The Hubbard Foundation, San Diego CA
spacer

Description of Tests

The Hubbard Foundation uses a 3T MRI to test for CCSVI according to the Haacke Protocol with an additional functional MRI (fMRI) test. The testing facility is the Applied fMRI Institute in San Diego, CA. Below is a chart of the tests including the CPT codes. We do not do Doppler Ultrasound.

Updated Price: $3,500

Test Duration: approximately 120 minutes

E. Mark Haacke, PhD a world-renowned MRI physicist at Wayne State University, has compiled a series of MRI scans designed to comprehensively evaluate the cerebral venous drainage system and the status of MS lesions.

MRI Test

CPT Code

Indication

MRI Brain W/ and W/O contrast

70553

Evaluate new and old plaques

      T1

 

 

      3D FLAIR

 

 

      3D SWI

 

 

 

 

 

MRA Head W/ and W/O contrast

70546

Evaluate venous anatomy flow in the venous sinuses of the brain

     Flow quantification

 

 

 

 

 

MRA Neck W/ and W/O contrast

70549

Evaluate venous anatomy and flow in the internal jugulars and azygous veins

      3D MRI (Dynamic)

 

 

      Hi-res MRA

 

 

 

 

 

FMRI BOLD

70555

Evaluate venous undershoot in cortex

Neurofunctional imaging

96020

Activate cerebral cortex BOLD response

The catheter angiography/ venoplasty is done by our Interventional Radiologists in Del Mar, San Diego and the hospital in Rancho Bernardo, San Diego.

 